Reasons and solutions for laser cutting machine not producing light

2024-05-19

There are usually three reasons why the laser tube of a laser cutting machine does not emit light: first, the laser tube suddenly does not emit light; second, the light using the laser tube becomes weaker and weaker; finally, everything starts working normally; the next day, the laser cutting machine starts up and there is no light.

Firstly, regarding the reason for the lack of light.

Solution: Check the water flow of the laser cutting machine in the water cycle to see if the water outlet pipe is short of water.

1. If the water outlet pipe flows normally, ask the customer how long it has been since startup (please answer truthfully, otherwise it will affect the correct judgment). If the customer claims to have used it for a morning or more than two hours, please ask the customer to check if there is water on the outermost layer of the carbon dioxide laser tube. If there is water, it is because the water temperature is too high and the laser tube is damaged (due to customer reasons).

2. If there is no water on the outer layer of the laser tube, we will check the laser power supply. There is a red button on the laser power supply. Press it to see if there is light. If there is light, it means that the water protection device is faulty. At this point, we request the customer to check if the water protection device is blocked. Then clean the water protection cover and wash it with water.

At this point, we need to be careful not to reverse the water inlet and outlet, otherwise the laser tube will be damaged. The second method is to short circuit the PG on the laser power supply (connected through a circuit), but at this time, pay attention to checking the water circulation. Water protection does not work, and the laser tube will still be damaged. If there is still no light, it means that the laser power supply is broken and needs to be replaced by the manufacturer.

Laser Cutting Machine

Secondly, regarding the reasons and solutions for the increasingly weak beam of laser tubes used

1. Check the water circulation of the laser machine. If the water flow does not circulate, please turn off the power and check if the water pump or chiller plug is plugged in.

2. Check if the ammeter of the laser cutting machine is functioning properly. If normal, it may be a problem with the laser tube. Please contact the manufacturer for replacement or repair. If the ammeter is not working properly, it is a problem with the laser power supply. Please contact the manufacturer for replacement or repair.

Finally, when you start using it, everything is normal, but when you open it the next day, there is no light left.

Solution: Check if the water circulation of the laser cutting machine is normal.

Check the ammeter of the laser cutting machine and press the "emergency light" to see if the pointer of the ammeter can be hit. If it is less than 5 milliamperes, it means that the power supply is interrupted. Please contact the manufacturer for replacement or repair.

If the ammeter does not move, check if our laser switch is turned on. If turned on, check if the laser power indicator light is on. If turned on, press the off button on the laser power supply to check if the current pointer has moved and is less than 5 milliamps. Then disconnect the laser power supply or set the maximum and minimum light intensities in the software to 50%. Then press to check if the ammeter pointer has reached 10-12 milliamps. If not achieved, it is a problem with the laser power supply or motherboard.

Get the latest price? We will reply as soon as possible (within 12 hours)